Products

Our product development takes place in top professional
R&D-departments, where our engineers are always working
to develop new innovative products in co-operation with our customers.

APN-114F

1 1/4" Corrugated copper cable

PRELIMINARY DATA SHEET


Amphenol feeder cables are designed for low loss connections from electronic transmission or reception units right up to the antenna. The cable features a smooth copper tube inner conductor, annular corrugation of the outer conductor and a highly foamed polyethelene dielectric for enhanced performance.

DESCRIPTION

  • Annular corrugated copper
  • Foamed polyethylene dielectric
  • PE outer jacket
  • 50 Ohm cable
  • Designed for low loss transmission lines

ORDERING DESIGNATIONS

PRODUCT CODE TYPE
APN-114F 1 1/4" Corrugated copper cable

SPECIFICATIONS

ELECTRICAL  
Characteristic Impedance 50 ±2 Ω
Relative velocity of propagation 88 %
Capacitance 78 nF/km (24.4 nF/1000ft)
Inductance 0.190 μH/m (0.059 μH/ft)
Maximum operating frequency 3.3 GHz
Cutoff frequency 3.7 GHz
Peak power rating 200 kw
Isolationelectrical strength 1000 V
Jacket spark, volts RMS 1000 V
MECHANICAL AND THERMAL CHARACTERISTICS
Inner conductor: Copper clad aluminum wire 12.9 mm / 0.508 in.
Dielectric Foamed polyethylene 32.5 mm / 1.280 in.
Diameter over outer conductor Corrugated copper tube 36.0 mm / 1.417 in.
Diameter over outer jacket PE 38.3 mm / 1.508 in.
Cable weight PE About 936 kg/km / 2.063 lb.
Tensile strength 2000 N
Min. bending radius, single 200 mm / 7.87 in.
Min. bending radius, repeated 390 mm / 15.35 in.
Number of bends, minimum (typical) 15 (50)
Recommended hanger spacing 1.2 m / 47.24 in.
Permissible temperature range, installation -40 °C (-40 °F) up to +60 °C (+140 °F)
Permissible temperature range, operation -55 °C (-67 °F) up to +85 °C (+185 °F)
Jacket: Polyethylene (PE) BK
Wall thickness about 1 mm (0.043 in) ø (38.3 ± 0.4) mm (1.508 ± 0.016 in)
Screen material acc. to DIN EN 13602 Cu-ETP-R
Jacket material acc. to DIN EN 50290-2-24(VDE 0819),table 1/2-L/MD (HD 624.4)
ATTENUATION VALUES and power ratings
Attenuation values typical at 20℃ ambient temperature; Mean power rating at 40℃ ambient temperature, ± 10%
Frequency
MHz
Attenuation
(dB/100m)
Mean power rating
(kW)
Frequency
MHz
Attenuation
(dB/100m)
Mean power rating
(kW)
0.5 MHz 0.56 198 824 MHz 2.5 3.85
1 MHz 0.08 145 894 MHz 2.58 3.66
1.5 MHz 0.1 114 900 MHz 2.59 3.6
2 MHz 0.11 99.7 925 MHz 2.64 3.58
10 MHz 0.25 41.2 960 MHz 2.71 3.5
20 MHz 0.36 29.9 1000 MHz 2.75 3.4
30 MHz 0.44 24.6 1250 MHz 3.15 2.94
50 MHz 0.57 19.1 1500 MHz 3.4 2.61
88 MHz 0.74 13.5 1700 MHz 3.82 2.4
100 MHz 0.79 12.9 1800 MHz 3.86 2.31
108 MHz 0.85 12.5 1900 MHz 3.98 2.2
150 MHz 0.99 10.3 2000 MHz 4.1 2.15
174 MHz 1.07 9.42 2100 MHz 4.24 2.07
200 MHz 1.16 8.81 2200 MHz 4.34 2.0
300 MHz 1.44 7.17 2500 MHz 4.69 1.84
400 MHz 1.67 6.03 2700 MHz 4.91 1.74
450 MHz 1.77 5.62 3000 MHz 5.23 1.62
500 MHz 1.9 5.27      
512 MHz 1.92 5.19      
600 MHz 2.1 4.71      
700 MHz 2.28 4.27      
800 MHz 2.43 3.9      

RELATED PRODUCTS

PRODUCT CODE PRODUCT DESCRIPTION
APNC-114N-NM N Type Male 1 1/4" Corrugated copper cables
APNC-114N-NF N Type Female 1 1/4" Corrugated copper cables
APNC-114N-DM 7/16 DIN Male 1 1/4" Corrugated copper cables
APNC-114N-DF 7/16 DIN Female 1 1/4" Corrugated copper cables
AGK-114 Grounding kit for 1 1/4" Corrugated copper cable
AHPT-114N  ?
ACK-114-1 Feeder Clamp for 1-1/4" Corrugated copper cable 1×1 single
ACK-114-2 Feeder Clamp for 1-1/4" Corrugated copper cable 1×2 single
ACK-114-3 Feeder Clamp for 1-1/4" Corrugated copper cable 1×3 single